v2n-soc-temperature
Prints the SoC die (junction) temperature once per second from a Linux/Yocto user-space app on the V2N Cortex-A55 cluster, through the portable alp_temperature_read_die_milli_c() in <alp/temperature.h>.
Source: examples/v2n/v2n-soc-temperature/. New in alp-sdk v0.17.0.
This is not the on-module ambient sensor. That one is alp_temperature_read_milli_c(), a deliberately separate API entry — but on V2N / V2M Linux it has no backend yet and returns ALP_ERR_NOSUPPORT. To read the on-module TMP112 on V2N today, use its natural-name chip driver, as v2n-temp-sensor does.
The SDK marks this example as not yet run on hardware; no board output has been captured.
What it shows
alp_temperature_read_die_milli_c(&milli_c)— the hottest die sensor, in signed milli-degrees Celsius.ALP_ERR_NOSUPPORThandling — returned when the build has no SoC thermal source (Zephyr / bare-metal, or a kernel with no matching thermal zone).- Sign-safe printing of a milli-degree value.
How it works
The Yocto backend reads /sys/class/thermal/thermal_zoneN/temp for every zone whose type starts with cpu-thermal — the RZ/V2N's two TSU units. Zones are chosen by type, never by index, because the index follows probe order. The kernel keeps ownership of the TSU; the app claims no peripheral.
board.yaml
som:
sku: E1M-V2N101
preset: e1m-x-evk
cores:
a55_cluster:
app: ./src
peripherals: []
diagnostics:
log_level: info
No meta-alp-sdk recipe packages this app yet, so tan build blocks the A55 slice with a yocto-recipe-missing warning rather than guess a bitbake target. Build it with the Yocto SDK.
Build (Yocto SDK)
. /opt/poky/<ver>/environment-setup-aarch64-poky-linux
cmake -B build -S . -DCMAKE_TOOLCHAIN_FILE=$OECORE_NATIVE_SYSROOT/usr/share/cmake/OEToolchainConfig.cmake
cmake --build build
Expected output
Copy build/v2n-soc-temperature to the target and run it. The output has this shape:
[soc-temp] v2n-soc-temperature
[soc-temp] sample 0: <whole>.<milli> degC
...
[soc-temp] done
See also
<alp/temperature.h>referencev2n-temp-sensor— the on-module TMP112v2n-ros2-som-temperature— the same reading published as a ROS 2 topic- Examples overview